Randell Manufacturing, Inc.
This manual provides information on installation, operating, maintenance,
troubleshooting & replacement parts for
2000 SERIES
REACH-INS
NOTIFY CARRIER OF DAMAGE AT ONCE.
It is the responsibility of the consignee to inspect the container upon receipt of same
and to determine the possibility of any damage, including concealed damage. Randell
suggests that if you are suspicious of damage to make a notation on the delivery
receipt. It will be the responsibility of the consignee to file a claim with the carrier. We
recommend that you do so at once.
520 S. Coldwater Road Weidman, Ml 48893-9683
Phone 1-800-621-8560 Fax 1-800-634-5369 www.randell.com
Vedere la pagina 0
1 2 3 4 5 6 ... 48 49

Sommario

Pagina 1 - REACH-INS

Randell Manufacturing, Inc. This manual provides information on installation, operating, maintenance, troubleshooting & replacement pa

Pagina 2

Freight Damage Any and all freight damage that occurs to a Randell piece of equipment as a result of carrier handling is not considered warranty, an

Pagina 3 - 1-800-621-8560

Unit Installation A. Receiving Shipment Upon arrival, examine the exterior of the shipping crate for signs of abuse. It is advisable that the shipping

Pagina 4

D. Locating Your New Unit The following conditions should be considered when selecting a location for your unit: 1. Floor load - The area on which th

Pagina 5

E. Installation Checklist After the final location of the unit has been determined refer to the following checklist prior to start up: 1. Check all e

Pagina 6

Figure B - Temperature control adjustments The control knob allows for temperature adjustments, with in the cabinet only. Turning the knob clockwise w

Pagina 7

Unit Operation Randell has attempted to preset the cold control for an average interior temperature of 38°F at the factory but due to varying ambient

Pagina 8 - Warranty Policies

Recommended cleaners for your stainless steel include the following: JOB CLEANING AGENT COMMENTS Routine cleaning Soap, ammonia, detergent Medallion

Pagina 9

SYMPTOM POSSIBLE CAUSE PROCEDURE UNIT DOESN'T RUN 1. NO POWER TO UNIT. 1. PLUG IN UNIT. 2. TEMPERATURE CONTROL TURNED OFF. 2. CHECK T

Pagina 10

SYMPTOM POSSIBLE CAUSE PROCEDURE UNIT TOO COLD 1. TEMPERATURE CONTROL SET TOO LOW. 1. ADJUST CONTROL. 2. TEMPERATURE CONTROL FAULTY. 2. TES

Pagina 11 - Unit Installation

1. Cleaning condenser coil. An accumulation of dirt and dust prevents the condenser coil from removing, making your unit cool poorly, run constantly,

Pagina 12

TABLE OF CONTENTS Page 2 ...…………...Congr

Pagina 13

4. Testing and replacing the temperature control. Unplug the unit and remove the temperature control knob. Remove the screws securing the fan shroud t

Pagina 14

6. Testing and replacing programmable defrost timer. With electric defrost it is critical that the defrost terminate at the earliest possible time. Th

Pagina 15 - Preventive Maintenance

7. Servicing the condenser fan. Inspect the condenser fan motor by removing the mechanical housing cover to gain access. Unplug the unit. Clean the fa

Pagina 16

To test the compressor relay pull the relay straight off the compressor without twisting it. If the relay has an external wire coil, hold the relay

Pagina 17

To test the compressor set a multimeter at RX1, test each of the three terminal pins against each of the other two. Each pair should show continuit

Pagina 18

o:/drafting/service/reachin.dgn Aug. 27, 1998 14:00:24

Pagina 19

o:/drafting/service/reachin.dgn Aug. 27, 1998 14:01:06

Pagina 20

o:/drafting/service/reachin.dgn Sep. 1, 1998 13:43:47

Pagina 21

o:/drafting/service/reachin.dgn Sep. 1, 1998 09:59:26

Pagina 22

o:/drafting/ser-vice/reachin.dgn Aug. 27, 1998 13:13:34

Pagina 23

Retain this manual for future reference. Notice: Due to a continuous program of product improvement, Randell Manufacturing reserves the right to make

Pagina 24

o:/drafting/service/reachin.dgn Aug. 27, 1998 13:12:53

Pagina 25

o:/drafting/service/reachin.dgn Aug. 27, 1998 13:13:14

Pagina 26

o:/drafting/service/reachin.dgn Aug. 27, 1998 13:08:21

Pagina 27

REACH-IN REFRIGERATOR REPLACEMENT PARTS LIST ITEM DESCRIPTION PART# 2 0 1 0 - 1 1 2 1 3 5 2 0 2 0 2 2 0 2 2 1 2 1 6 8 2 0 3 0

Pagina 28

REACH-IN REFRIGERATOR REPLACEMENT PARTS LIST ITEM DESCRIPTION PART# 0 0 1 0 1 1 9 1 3 5 0 0 2 0 2 1 2 0 2 2 2 1 6 8 2 0 3 0

Pagina 29

REACH-IN REFRIGERATOR REPLACEMENT PARTS LIST ITEM DESCRIPTION PART# 2 2 2 2 2 2 0 1 0 0 1 0 1 3 2 2 6 3

Pagina 30

REACH-IN FREEZER MODELS REPLACEMENT PARTS FREEZER ITEM DESCRIPTION PART # 2010F 2011F 2235 2020F 2021 F 2268 2030F 2031 F 3 SET OF (4) CASTERS

Pagina 31

REACH-IN FREEZER MODELS REPLACEMENT PARTS FREEZER ITEM DESCRIPTION PART# 2010F 2011F 2235 2020F 2021F 2268 2030F 2031F 110 PLUG (HUBBELL) 20 A

Pagina 32

REACH-IN FREEZER MODELS REPLACEMENT PARTS FREEZER ITEM DESCRIPTION PART# 2010F 2011F 2235 2020F 2021 F 2268 2030F 2031 F 413 DEFROST ELEMENT (

Pagina 33

DUAL TEMPERATURE REACH-INS REPLACEMENT PARTS ITEM DESCRIPTION PART# 2010D 2020D 3 SET OF (4) CASTERS 001451 X X 4 CASTER 6" NON-LOC

Pagina 34 -

RANDELL MANUFACTURING SERIAL NUMBER LOCATION FOR THE 2000 SERIES This is a sample of a serial number

Pagina 35

DUAL TEMPERATURE REACH-INS REPLACEMENT PARTS ITEM DESCRIPTION PART # 2010D 2020D 118A THERM-O-DISC 3-WIRE RF-TRM002 X X 119 DEFROST TIME

Pagina 36

Unit Specifications For The 2000 Series Heated Reach-ins 5 Roll-ins MODE L L D H DOORS CUBIC FT kW* VOLT AMP* NEMA SHIP WT 2410

Pagina 37

Serial Number Location The serial number tag for the heated units is located on the far left inside of the base. Unit Installation Please refer to uni

Pagina 38

Preventive Maintenance Randell strongly suggests a preventive maintenance program which would include the following Monthly procedures: 1. Cleaning of

Pagina 39

For more information on preventive maintenance consult your local service company or CEFSA member. Most repair companies offer this service at very re

Pagina 40

SYMPTOM POSSIBLE CAUSE PROCEDURE UNIT DOESN'T RUN 1. NO POWER TO UNIT. 1. PLUG IN UNIT. 2. TEMPERATURE CONTROL TURNED OFF. 2. CHECK T

Pagina 43

2400 SERIES HEATED REACH-INS MODELS ITEM DESCRIPTION PART# 2410 2420 2335 2368 3 CASTERS SET OF 4 001451 X X 4 REACH-IN NONLOCKING

Pagina 44

Randell Manufacturing., Inc. Authorized Parts Distributers DEPOT #1 CASE PARTS CO. 877 Monterey Pass Road Monterey Park, CA 91754 1-800-621-7884 (CAO

Pagina 45

Unit Specifications For The 2000 Series 2000 SERIES MODEL L D H DOORS CUBIC FEET SHELVES QTY/SQ. FT HP** BTU/HR VOLT AM

Pagina 46

2000 SERIES MODEL L D H DOORS CUBIC FEET SHELVES QTY/SQ FT. HP BTU/HR VOLT AMP NEMA SHIP WT 2020

Pagina 47

2000 SERIES MODEL L D H DOORS CUBIC FEET SHELVES QTY/SQ FT HP** BTU/HR* VOLT AMP NEMA SHIP WT 2030 83" 33.5" 81.25" 3

Pagina 48

Randell Manufacturing, Inc. Warranty Policies Parts Warranty Randell warrants all component parts of manufactured new equipment to be free of defects

Pagina 49 - Randell Manufacturing., Inc

Five Year Extended Compressor Warranty United States installations only: Randell will pay for the replacement compressor only. Freight, labor, refri